DEVI DEVIreg 535 Instalační manuál

Procházejte online nebo si stáhněte Instalační manuál pro Termostaty DEVI DEVIreg 535. DEVI DEVIreg 535 Installation manual [en] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Installation manual

DeviregTM 535Installation manualWarning!This manual is only to be used by a professional installer to install and set up the thermostat properly.It

Strany 2 - Congratulations with…

10DeviregTM 535 is an electronic timer temperature controller, specially designed for floor heating systems. The DeviregTM 535, once set, automatically

Strany 3 - Table of content

INT11WeekdaysSettingsRoom temperatureFrost protectionDay rhythm periods and comfort / econo-my temperatureChildproof Actual temperature is dis

Strany 4

12MorningDayEveningNightTimer functionThe day is divided into 4 time periods analogous to the typical day pro-gramming pattern:- Morning- Day- Evening

Strany 5 - Installation and connection

INT134 different programs can be selectedFactory setting is Program 1. Manual mode.The 4 programsProgram 1 Manual mode. The temperature is main-tained

Strany 6 - Choose sensor combination

14Factory settingsFloor sensor onlyRoom sensor onlyFloor and Room sensorTemperature:Comfort 25°C 21°C 21°CEconomy 5°C 17°C 17°CPeriods – Day rhythm

Strany 7 - Configuration - sensor

INT15During the timer programs, P2, P3, and P4, the flashing indicates the actual time period.In program 4 the actual day is also shown.Using the arr

Strany 8 - ▲▼ for the next setting

16Settings overviewSettingsAll settings are under the settings menu. Here you set the following:- Time- Weekday- Timer periods configuration(Morning,

Strany 9 - Configuration - Scale

INT17You enter the settings by pressing the pinhole with a small screw driver, pencil, or needle, the display now changes from temperature to time d

Strany 10 - User’s guide to Devireg

18Setting the timer periodsWhen programming the starting times of the 4 periods keep in mind that the thermostat will start heating/stop heating at th

Strany 11 - ▲▼ to either increase

INT19Setting the comfort temperatureBy pressing the • the preset comfort tempera-ture starts flashing.You change it with the arrow buttons ▲▼Press th

Strany 12 - Timer function

2... your DEVI floor heating systemYour property has been installed with a DEVI electric floor heating system. DEVI is Europe’s leading floor heating man

Strany 13 - The 4 programs

20Special featuresChildproof modeYou disable all buttons in child proof mode by pressing the pinhole button below with a small screw driver, pencil,

Strany 14 - Factory settings

INT21OFF modeTo set the thermostat in OFF mode, you hold down ▼ until you reach 5.0°. Now press ▼ again twice to verify that you are not just changing

Strany 15 - Changing timer program

22Special features / Trouble shootingSwitching displayed temperatureDepending on what mode the thermostat is installed as (floor, or a combination of fl

Strany 16 - Settings overview

INT23E4 flashing in display: Error code 4 – The thermostat has overheated and has switched offLet the thermostat cool for period. Then switch the thermo

Strany 17 - Changing the settings

24Operation voltage 180-250 VAC, 50/60 HzStandby power consumptionMax. 0.30 WRelay: • Resistive load• Inductive load230V ~ 15A / 3450Wcos φ= 0.3 Max.

Strany 18

INT25All electric or electronic equipment and enclosed batteries containing materials, components and substances that can be harmful to people’s healt

Strany 19

26The 2 Year DEVI Warranty:You have purchased a DEVI heating system which we are sure will serve to improve the comfort and economy of your applicatio

Strany 20 - Special features

INT27The DEVITM Guarantee is granted to:Name:Country:2 YEAR WARRANTYWarranty CertificateAddress:City:Electrical installation by:Material number:Type o

Strany 21

Article No.: 08095880Version - 01.01 VICKI202 06/2009DEVI A/S Ulvehavevej 61DK-7100 Vejle Tel: +45 74 88 85 00Fax: +45 74 88 85 01www.devi.com

Strany 22

INT3Table of content Table of content Install & configure the thermostat . . . . . . . . . . . . . . . . . . . . . .4 Placement of DeviregTM

Strany 23 - Trouble shooting

4Placement of DeviregTM 535When DeviregTM 535 is used as a room sensor, installation height should typically be between 80-150 cm.At least 50 cm away

Strany 24 - Technical specifications

INT5N LInstallation of DeviregTM 5351. To remove the front cover, gently press the release tabs under the bottom of the thermostat with a screwdr

Strany 25 - Disposal Instruction

63. Choose sensor combination When installing the Devireg™ 535 you need to choose the type of heating and thus which sensors should be used. Y

Strany 26 - The 2 Year DEVI Warranty:

INT7Selection of sensor typePower on the thermostat.With the front off, with a small screw-driver, pencil, or needle press the installation button.Sele

Strany 27 - 2 YEAR WARRANTY

8Notice:The floor temperature is measured where the sensor is placed. The temperature of the bottom of a wooden floor can be up to 10 degrees higher tha

Strany 28 - Version - 01.01

INT9ScaleIf you select DeviregTM 535 to only use a floor sensor, mode , you have to select the display type. The choice is either numerical scale 1-6

Komentáře k této Příručce

Žádné komentáře