*A qualified electrician must carry out all instructions within a shaded box.
HEATING ISSUE 1
The RCD trips out
when the system is
turned on.
HEATING ISSUE 2
There is no display on
the thermostat.
An electrician should
visit the site to ensure all
electrical connections
and wiring are correct.
Are they correct?
Is there an earth fault?
(Continuity between
live/earth or
earth/neutral).
Exchange
thermostat. Is the floor
warming up?
Please complete the
visual checks on page 3.
Does the product pass
all three checks?
Please complete
sections 1 and 2, and
return to DEVI.
You will be contacted as
soon as possible.
Please wait 24 hrs to
evaluate how the system
is performing.
Is the floor warming up
at all?
Please complete
sections 1 and 5 and
return to DEVI. You will
be contacted as soon as
possible.
Purchase a
replacement thermostat
The electrician should
conduct a resistance and
insulation test.
Is there an open circuit?
(No resistance).
Please complete
sections 1 and 2 and
return to DEVI.
You will be contacted as
soon as possible.
Please make changes to
the wiring/connections
by using the diagrams
available at
www.devi.co.uk.
Also refer to the back
of the thermostat.
Please complete sections
1 and 3 and return 550
to your supplier.
Is there a voltage output
from the thermostat
when required? Please
use the test instructions
on page 5/6 to set the
thermostat.
Please complete
sections 1 and 4 and
return to DEVI. You will
be contacted as soon
as possible.
Please use
the system as
required.
YES
YES
(heating issue 2 only)
Please follow the step-by-step instructions and