Visual checks
VISUAL CHECK ONE
Cracked LCD display
This fault is caused when someone
attempts to remove the front cover of
the thermostat. This is normally
removed by carefully pushing down
on the plastic tab in the top central
grill. If care is not taken, the
implement used to push down the
tab slips and damages the display,
causing it to crack. This damage can
also be caused by over-tightening of
the screws.
This fault is caused when the
electrics entering the back of the
thermostat are stripped back too far,
exposing the live conductors. When
this happens, if these exposed wires
cross, they short and cause the fuse
to blow and the back of the
controller to be blackened.
Remove the front cover and inspect
the back of the LCD display. At the
back are a set of gold connector
pins, these leave the factory
straight, if they are bent or
distorted then a heavy hand has
been used to plug the display into
the base of the thermostat.
VISUAL CHECK TWO
Blackening at the rear of the
thermostat
VISUAL CHECK THREE
Bent pins
These instructions will help to identify whether the fault with your underfloor heating system has been
caused due to mis-installation/not following user instructions.
If these VISUAL checks are carried out correctly, the thermostat may not have to be returned to DEVI,
which will save you time.
In all three examples, the thermostat would not be covered by the DEVI Warranty.